1、Technical background
 
According to the 2010 edition of GMP for sterile drug production requirements: when aseptic operation was underway, special attention should be paid to reduce all kinds of activities, within the clean area staff move should control, and should be very careful to avoid strenuous activity with too many particles and microorganisms, while the sterile operation number within the clean area should be strictly controlled, inspection, supervision and operation should be clean area as far as possible in the aseptic operation outside of the.
 
By the device in the C region, RABS docking discharge port and B+A regions, a sterilization since the device to the RABS region of B+A, fully automatic continuous operation, changed the discharging door with isolation and transfer on the solution of mobile laminar car, tedious, and increase the risk of uncertain factors at the same time, also increase input, selection of the equipment, small investment, the risk small and controllable, more convenient, truly realize the sterilization to the filling full closed automatic shift.

      

2、The scope of application
 
Heat resistant material and equipment is suitable for sterile drug production such as: cans, glass bottles, metal parts and other appliances utensil sterilization, removing pyrogen.

 

3、Principle

This equipment sterilization and cooling zone, sterilization, circulating fan, heater, exhaust fan, rapid heating, hot air into the cavity through the effectivefilter, absorb water surface material, into the circulation channel evaporation discharge, and both sides of the cavity is the special structure of the wind board, cavity the formation of micro positive pressure, temperature, constant temperature sterilization, when the material sterilization / in addition to heat after hot, back door opens, a sterilization will automatically enter the cooling zone cooling, at the same time zone door closes automatically,feeding door can be opened again into the material, RABS material in the cooling zone temperature automatically into B+A end after filling.

4、Technical characteristics

1, automatic sealing transfer, the whole process does not need operation, completely solve the pollution risk of personnel;

2, the cabinet door sealing, effectively blocking the pollution, the outside air for sterilization articles patent number: ZL 201120410545.1

3, the cavity filter using negative pressure cycle sealing, no seal, to avoid the particle pollution, seals aging produced patent number: ZL2011 20402354

4, control system using Siemens PLC+HMI, reliable operation, convenient operation;

5, set up an independent recording system, operation parameters online record time, temperature, and can be stored and printed;

6, the heating and cooling equipment to separate settings, can realize continuous production, improve production efficiency, saving energy.

5、Main technical parameters

Model

Dimension of working chamber
W×D×Hmm

Overall dimension
W×D×Hmm

Installed capacity
KW

Power supply
V

Temperature range

Temperature uniformity

Production capacity

Aluminum listen

 

Compressed air consumption
L/h

DMH-AD3

2570×630×450

3100×1400×2320

17

380V-50HZ

50-250

±3

5Kg 3pcs/h

2.5-5

DMH-AD6

3780×630×450

4130×1400×2520

28

380V-50HZ

50-250

±3

 5Kg 6pcs/h

2.5-5

DMH-AD10

3500×1050×450

3850×1820×2470

32

380V-50HZ

50-250

±3

 5Kg 10pcs/h

5-10

DMH-AD12

3780×1050×450

4130×1820×2520

35

380V-50HZ

50-250

±3

 5Kg 12pcs/h

5-10

Can be designed and manufactured on site accroding to user’s requirements.

 